15-23/04/2011
Cairo International Fair (CIF) 2011
      Cairo International Fair (CIF) – is an annual event organized by the Egypt Expo & Convention Authority EECA; under the auspices of the Ministry of Industry and Foreign Trade  It  aims  to create favorable conditions for local and foreign enterprises and trade organizations to search for business  partners; expand markets; develop production, business and import – export activities; as well as showcasing new products and services. 
...............................................................



7-9/04/2011
CHINA REFRIGERATION 2011
      China Refrigeration is the biggest exhibition in China, it held once a year. The exhibition is for refrigeration, Air–conditioning, Heating and Ventilation, Frozen Food Processing, Packaging and Storage. And it has been focusing on extending the groups of end–users and professional buyers. “ China Refrigeration Expo. ” is not only a showcase of the latest technology and publication of the most popular products, but also a good opportunity interpreting policy, assisting enterprises to improve quality and achieving sustainable development goal.
...............................................................



1-4/03/2011
CLIMATIZACION 2011

      Climatizacion is held every 2 years and is one of the leading trade fairs  for air conditioning, ventilation, cooling and heating technology in Europe. Manufacturers from all over the world show their latest products such as air conditioners, heat exchangers, cooling, refrigeration,hot water generators and much more. Climatizacion is mainly visited by architects, civil engineers, installers and retailers and wholesaler to get to know the innovations and trends of the industry. It serves as a platform to expand business relationships or to make and maintain contacts.

 ...............................................................



13-15/10/2010
CHILLVENTA 2010

       Chillventa is a big Exhibition and normally there are over 800 internal exhibitors and more than 29,000 trade visitors to attend the show. Chillventa focuses on: Refrigeration, Air conditioning, Ventilation and Heat pumps. Its core theme is the thermodynamic refrigeration process and all the associated applications, equipment and services.
...............................................................

 

 
Account due date (KK, KPC)
 |   

 


<123456>Last ›

Model BOM ID Disp Voltage Hz. Refr. App Motor Capacity - ASHRAE Input COP EER
    (CC)         type (W) (BTU) (W)  
AE 1370Y 07N 8.12 220-240 50 R134a LBP R.S.I.R. 180 / 0 614 / 0 169 / 0 1.07 / 0.00 3.65 / 0.00
AE 1370Y 143 8.12 220-240 50 R134a LBP R.S.I.R. 186 / 0 635 / 0 160 / 0 1.16 / 0.00 3.96 / 0.00
AE 1370Y 044 12.05 220-240 50 R12 LBP C.S.I.R. 270 / 0 921 / 0 267 / 0 1.01 / 0.00 3.45 / 0.00
AE 1370Y 16A 8.12 220-240 50 R134a LBP RSIR 186 / 0 635 / 0 160 / 0 1.16 / 0.00 3.96 / 0.00
AE 1370Y-2 144 8.12 208-230 60 R134a LBP R.S.I.R. 210 / 0 717 / 0 184 / 0 1.14 / 0.00 3.89 / 0.00
AE 1370Y-4H 469 8.12 110 60 R134a LBP R.S.C.R. 235 / 0 802 / 0 180 / 0 1.31 / 0.00 4.47 / 0.00
AE 1370Y-H 219 8.12 220-240 50 R134a LBP R.S.C.R. 200 / 0 682 / 0 152 / 0 1.32 / 0.00 4.50 / 0.00
AE 1380AK 035 8.84 220-240 50 R12 LBP R.S.I.R. 194 / 0 662 / 0 212 / 0 0.92 / 0.00 3.14 / 0.00
AE 1380AK 16T 8.86 220-240 50 R12 LBP RSIR 194 / 0 662 / 0 167 / 0 0.92 / 0.00 3.14 / 0.00
AE 1380AK-2 039 8.86 208-230 60 R12 LBP R.S.I.R. 256 / 0 873 / 0 243 / 0 1.05 / 0.00 3.58 / 0.00
AE 1390VK 040 8.86 220-240 50 R12 LBP R.S.I.R. 230 / 0 785 / 0 190 / 0 1.21 / 0.00 4.13 / 0.00
AE 1390VK-2 041 8.12 208-230 60 R12 LBP R.S.I.R. 250 / 0 853 / 0 218 / 0 1.15 / 0.00 3.92 / 0.00
AE 1390Y 07P 9.42 220-240 50 R134a LBP R.S.I.R. 252 / 0 860 / 0 192 / 0 1.31 / 0.00 4.47 / 0.00
AE 1390Y 145 9.42 220-240 50 R134a LBP R.S.I.R. 252 / 0 860 / 0 192 / 0 1.31 / 0.00 4.47 / 0.00
AE 1390Y-6 415 9.42 220 50/60 R134a LBP R.S.I.R. 255 / 297 870 / 1,013 203 / 236 1.26 / 1.26 4.30 / 4.30
AE 1390Y-H 213 9.42 220-240 50 R134a LBP R.S.C.R. 265 / 0 904 / 0 192 / 0 1.38 / 0.00 4.71 / 0.00
AE 1390YK 225 9.42 220-240 50 R134a LBP R.S.I.R. 252 / 0 860 / 0 192 / 0 1.31 / 0.00 4.47 / 0.00
AE 1410VK 043 9.42 220-240 50 R12 LBP R.S.I.R. 270 / 0 921 / 0 232 / 0 1.16 / 0.00 3.96 / 0.00
AE 1411Y 334 14.14 220-240 50 R134a LBP R.S.I.R. 298 / 0 1,017 / 0 252 / 0 1.18 / 0.00 4.03 / 0.00
AE 2340Y 272 5.11 220-240 50 R134a LBP C.S.I.R. 110 / 0 375 / 0 107 / 0 1.03 / 0.00 3.51 / 0.00
AE 2360AK 411 7.55 220-240 50 R12 LBP C.S.I.R. 165 / 0 563 / 0 168 / 0 0.98 / 0.00 3.34 / 0.00
AE 2360Y 270 6.91 220-240 50 R134a LBP C.S.I.R. 158 / 0 539 / 0 136 / 0 1.16 / 0.00 3.96 / 0.00
AE 2360Y-3 446 6.91 100 50/60 R134a LBP C.S.R. 175 / 200 597 / 682 155 / 183 1.13 / 1.09 3.86 / 3.72
AE 2360Y-SR 353 6.91 220-240 50 R134a LBP C.S.R. 158 / 0 539 / 0 119 / 0 1.33 / 0.00 4.54 / 0.00
AE 2370VK 240 6.91 220-240 50 R12 LBP C.S.I.R. 173 / 0 590 / 0 147 / 0 1.18 / 0.00 4.03 / 0.00
AE 2370VK-SR 254 6.91 220-240 50 R12 LBP C.S.R. 173 / 0 590 / 0 130 / 0 1.33 / 0.00 4.54 / 0.00
AE 2370Y 241 8.12 220-240 50 R134a LBP C.S.I.R. 185 / 0 631 / 0 163 / 0 1.13 / 0.00 3.86 / 0.00
AE 2370Y-2SR 266 8.12 208-230 60 R134a LBP C.S.R. 220 / 0 751 / 0 170 / 0 1.29 / 0.00 4.40 / 0.00
AE 2370Y-3 147 8.12 100 50/60 R134a LBP C.S.R. 208 / 237 710 / 809 180 / 216 1.16 / 1.10 3.96 / 3.75
AE 2370Y-SR 265 8.12 220-240 50 R134a LBP C.S.R. 185 / 0 631 / 0 143 / 0 1.29 / 0.00 4.40 / 0.00

Home | About Us | Press / News | Photo Gallery | Investor Relations | Products | Marketing | Contact Us
All rights reserved © 2008 Kulthorn Kirby Public Co., Ltd. Powered by gen!us